Fault Detection in Underground Cable by using Arduino

Authors

  • Jyoti M Kharade Associate Professor, Department of Electrical Engineering, Annasaheb Dange College of Engineering & Technology, Ashta, Maharashtra, India

DOI:

https://doi.org/10.5281/zenodo.15386738

Keywords:

arduino nano, underground fault, resistance, lcd

Abstract

This paper presents the system to ascertain the length of faulty cable in kilometres by employing NANO ARDUINO outfit. In numerous Municipal fields, the underground cable method is employed. When faults or abnormalities occur due to any reason, it is difficult to rectify the quandary because of not perceiving the exact location of the fault. The proposed method is to localize the exact location or spot of the fault. The system employs the standard principle of Ohm’s Law i.e. the current changes depending upon the fault distance, where small voltage is employed at feeder end over series resistors. Consequently the voltage across the resistors alters which is calibrated in distance after feeding the data to inherent ADC of NANO ARDUINO outfit, and displayed on digital seven segment display. The hardware system is designed in such manner the series resistors, which are depicting cable length in kilometres, and short circuit fault formation is done with the switches at each comprehend kilometre to verify the correctness of the design. Hereafter, the work will be amplified with the application of capacitor in an AC system for finding the impedance, which will localize the open circuit in underground cable.

Downloads

Download data is not yet available.

References

Abhishek Pandey, & Nicolas H. Younan. (2010). Underground cable fault detection and identification via fourier analysis. IEEE.

H. Shateri. (2012). Impedance based fault location method for phase to phase and three phase faults in transmission systems. 11th IET International Conference on Developments in Power Systems Protection.

Md. Fakhrul Islam, et al. (2013). Locating underground cable faults: A review and guideline for new development. IEEE.

N.Gayathri, et al. (2018), Automatic underground cable fault detection with sms alert. International Research Journal of Engineering and Technology (IRJET), 05(02), 2077-2080.

P.S Pooja. (2015). Fault detection technique to pinpoint incipient fault for underground cables. International Journal of Engineering Research and General Science, 3(3), 1580-1587.

S. Navaneethan. (2001). Automatic fault location for underground low voltage distribution networks. IEEE Transactions on Power Delivery, 16(2), 346-351.

Xia Yang. (2008). Fault location of underground power cable using distributed parameter approach. IEEE Trans. Power System, 23(4), 1809-1816.

Yu Xiang. (2015). A bayesian approach for fault location in medium voltage grids with underground cables. IEEE Power and Energy Technology Systems Journal, 2(4), 116-124.

Published

2025-03-29

How to Cite

Kharade, J. M. (2025). Fault Detection in Underground Cable by using Arduino. Applied Science and Engineering Journal for Advanced Research, 4(2), 63–66. https://doi.org/10.5281/zenodo.15386738

Issue

Section

Articles

ARK

Most read articles by the same author(s)